ARM: dts: qcom: msm8226: Hook up CPU cooling
Add cooling-maps for the CPU thermal zones so the driver can actually do something when the CPU temperature rises too much. Signed-off-by: Luca Weiss <luca@lucaweiss.eu> Reviewed-by: Konrad Dybcio <konrad.dybcio@linaro.org> Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> Link: https://lore.kernel.org/r/20240619-msm8226-cpufreq-v1-6-85143f5291d1@lucaweiss.eu Signed-off-by: Bjorn Andersson <andersson@kernel.org>
This commit is contained in:
parent
02f2ddaa1a
commit
807dfab845
|
|
@ -12,6 +12,7 @@
|
|||
#include <dt-bindings/gpio/gpio.h>
|
||||
#include <dt-bindings/power/qcom-rpmpd.h>
|
||||
#include <dt-bindings/reset/qcom,gcc-msm8974.h>
|
||||
#include <dt-bindings/thermal/thermal.h>
|
||||
|
||||
/ {
|
||||
#address-cells = <1>;
|
||||
|
|
@ -48,6 +49,7 @@ CPU0: cpu@0 {
|
|||
operating-points-v2 = <&cpu_opp_table>;
|
||||
qcom,acc = <&acc0>;
|
||||
qcom,saw = <&saw0>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
CPU1: cpu@1 {
|
||||
|
|
@ -60,6 +62,7 @@ CPU1: cpu@1 {
|
|||
operating-points-v2 = <&cpu_opp_table>;
|
||||
qcom,acc = <&acc1>;
|
||||
qcom,saw = <&saw1>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
CPU2: cpu@2 {
|
||||
|
|
@ -72,6 +75,7 @@ CPU2: cpu@2 {
|
|||
operating-points-v2 = <&cpu_opp_table>;
|
||||
qcom,acc = <&acc2>;
|
||||
qcom,saw = <&saw2>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
CPU3: cpu@3 {
|
||||
|
|
@ -84,6 +88,7 @@ CPU3: cpu@3 {
|
|||
operating-points-v2 = <&cpu_opp_table>;
|
||||
qcom,acc = <&acc3>;
|
||||
qcom,saw = <&saw3>;
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
L2: l2-cache {
|
||||
|
|
@ -1256,6 +1261,16 @@ cpu0-thermal {
|
|||
|
||||
thermal-sensors = <&tsens 5>;
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert0>;
|
||||
cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
|
||||
trips {
|
||||
cpu_alert0: trip0 {
|
||||
temperature = <75000>;
|
||||
|
|
@ -1277,6 +1292,16 @@ cpu1-thermal {
|
|||
|
||||
thermal-sensors = <&tsens 2>;
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert1>;
|
||||
cooling-device = <&CPU0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&CPU1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&CPU2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&CPU3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
|
||||
trips {
|
||||
cpu_alert1: trip0 {
|
||||
temperature = <75000>;
|
||||
|
|
|
|||