HID: hid-input: only ignore 0 battery events for digitizers

Commit 581c448476 ("HID: input: map digitizer battery usage") added
handling of battery events for digitizers (typically for batteries
presented in stylii). Digitizers typically report correct battery levels
only when stylus is actively touching the surface, and in other cases
they may report battery level of 0. To avoid confusing consumers of the
battery information the code was added to filer out reports with 0
battery levels.

However there exist other kinds of devices that may legitimately report
0 battery levels. Fix this by filtering out 0-level reports only for
digitizer usages, and continue reporting them for other kinds of devices
(Smart Batteries, etc).

Reported-by: 卢国宏 <luguohong@xiaomi.com>
Fixes: 581c448476 ("HID: input: map digitizer battery usage")
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
This commit is contained in:
Dmitry Torokhov 2025-10-14 21:28:44 -07:00 committed by Jiri Kosina
parent a7cdc2086c
commit 0187c08058
1 changed files with 4 additions and 1 deletions

View File

@ -635,7 +635,10 @@ static void hidinput_update_battery(struct hid_device *dev, unsigned int usage,
return;
}
if (value == 0 || value < dev->battery_min || value > dev->battery_max)
if ((usage & HID_USAGE_PAGE) == HID_UP_DIGITIZER && value == 0)
return;
if (value < dev->battery_min || value > dev->battery_max)
return;
capacity = hidinput_scale_battery_capacity(dev, value);